Introduction

Standard parameters: ECG SPO2 NIBP RESP TEMP PR

Optional parameters: 2-IBP,thermal printer,ETCO2

 

Main Features

¦Display mode: 12'' color TFT LCD with high-resolution.

¦Be applicable for adult, pediatric and neonatal for all-round monitoring.

¦Operation interface with Chinese and English. (Optional languages: French, German, Italian, Turkish, etc.)

¦Multiple display modes are optional, such as big characters interface.

¦Waveform and data colour can be set optionally.

¦Storage of 480-hour trend data, and review of 40-second holographic waveform.

¦7-lead ECG displays in a screen, and ECG waveforms series display.

¦Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads).

¦Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability.

¦Function of NIBP review, storage for up to 400 NIBP data.

¦Connect central monitoring station, other bed observation and software updating with wireless and wired mode.

¦Built-in SD card, U disk for storing data and U disk updating.

¦Support the functions of VGA video output and adjustable LCD backlight.

¦Support alarm with human voice body.

¦Function of synchronous signal output.

¦Three operation modes: monitoring, surgery and diagnosis.

¦Auto-analysis for arrhythmia waveform.

¦Calculation function for drug concentration and titration table.

¦Dual-channel temperature monitoring, and with temperature error display.

¦NIBP dual-overpressure protection with software and hardware.

¦Built-in rechargeable lithium battery for uninterrupted monitoring.

¦The product has passed FDA certification in America and CE certification in Europe.

Feature:

NIBP:

¦ Method: Oscillometry

¦ Modes: Manual/Auto/Comtinuous

¦ Auto measure time:Adjustable

¦ Measurement rang:10-270mmHg

ECG:

¦ Lead mode:3-lead or 5-lead

¦ Lead selection:I;II;III;avR;avL;avF;V

¦ Heart rate range:Adult:15-300bpm;Pediatric/Neonatal:15-300bpm

¦ ECG waveform: 2 channals

¦ Accuracy: ± 1 bpm or ±1%

¦ S-T segment detection Measurement rang :-0.2mv~2.0mv

¦ Alarm:Yes,audible and visual alarm,alarm events review

¦ High resolution 12.1"color TFT display

¦ Lightweight,compact and portable

¦ ECG,APO2,NIBP,RESP,2-TEMP,PR

¦ Optional:2-IBP,ETCO2,And thermal printer

¦ Bulit-in rechargeable lithium battery

¦ ECG waveforms of 7-leads display on the same screen

¦ 72-hours graphic and tabular trends of all parameters

¦ 72 alarm events of all parameters recall

¦ 32 seconds full-disclosure waveform review

¦ 500 NIBP measurement date can be storage and recall

¦ Date and waveforms color be adjustable

¦ Arrhythmia analysis and S-T segment analysis

¦ Suitable for adult,pediatric and neonatal patient

SPO2

¦ Measurement range:0-100%

¦ Accyracy:70-100%, ±2% 0-69%,upspecified

Pulse rate

¦ Range:20-254bpm

¦ Accuracy: ±3bpm

Respiration

¦ Method:RA-LL impedance

¦ Range:Adult:0-120rpm;pediatric/neonatal:0-150rpm

¦ Apnca alarmYes

Temperature

¦ Range:0-50?

¦ Apnca: 0.1?

¦ Channal:Dual-Channal

? IBP
¦ Channel: 2 channels
 
¦ Pressure transducer: Sensitivity: 5( mV/V/mmHg)
 
¦ Transducer sites: ART, PA, CVP, RAP, LAP, ICP
 
¦ Alarm range: -10~300mmHg
 
? ETCO2
¦ Measurement Mode: Side-stream or mainstream
¦ Measurement range: EtCO2: 0-99mmHg
 
¦ Accuracy: CO2 concentration
 
¦ Apnea alarm: YES
 

Standard parameters: 

ECG SPO2 NIBP RESP TEMP PR 

 

Optional: 

2-IBP,thermal printer,ETCO2 ( MAY NEED EXTRA 2-3 WEEKS TO DELIVERY)